Skip to main content

Respiratory system compliance at the same PEEP level is similar in COVID and non-COVID ARDS

Abstract

Background

The comparison of respiratory system compliance (Crs) between COVID and non-COVID ARDS patients has been the object of debate, but few studies have evaluated it when considering applied positive end expiratory pressure (PEEP), which is one of the known determinants of Crs itself. The aim of this study was to compare Crs taking into account the applied PEEP.

Methods

Two cohorts of patients were created: those with COVID-ARDS and those with non-COVID ARDS. In the whole sample the association between Crs and type of ARDS at different PEEP levels was adjusted for anthropometric and clinical variables. As secondary analyses, patients were matched for predicted functional residual capacity and the same association was assessed. Moreover, the association between Crs and type of ARDS was reassessed at predefined PEEP level of 0, 5, 10, and 15 cmH2O with a propensity score-weighted linear model.

Results

367 patients were included in the study, 276 patients with COVID-ARDS and 91 with non-COVID ARDS. The association between Crs and type of ARDS was not significant in both the complete cohorts (p = 0.17) and in the matched cohorts (p = 0.92). This was true also for the propensity score weighted association at PEEP 5, 10 and 15 cmH2O, while it was statistically significant at PEEP 0 (with a median difference of 3 ml/cmH2O, which in our opinion is not clinically significant).

Conclusions

The compliance of the respiratory system is similar between COVID ARDS and non-COVID ARDS when calculated at the same PEEP level and while taking into account patients’ anthropometric characteristics.

Background

Acute respiratory distress syndrome (ARDS) is common in severe novel coronavirus 2019 disease (COVID-19) [1]. Recently, it was suggested [2] that respiratory system compliance (Crs) might be different in COVID-ARDS when compared to ARDS from other diseases, due to the existence of two different “phenotypes” in COVID ARDS which might not be present in non-COVID ARDS. These phenotypes have been identified as Type L, characterized by Low elastance (i.e., high compliance) and Type H, characterized by High elastance (i.e., low compliance) [2]. Subsequent studies have compared Crs between COVID ARDS and non-COVID ARDS, but the debate concerning differences in Crs between COVID and non-COVID ARDS patients is still ongoing, due to conflicting findings [3,4,5,6].

Crs is modified by Positive End Expiratory Pressure (PEEP) levels [7,8,9,10,11], but previous studies have compared Crs between COVID ARDS and non-COVID ARDS at different PEEP levels [3, 5, 12]. Only by knowing Crs at similar PEEP levels can the Crs of COVID and non-COVID ARDS patients be correctly compared, thus avoiding attributing to respiratory system characteristics what could be the effect of PEEP itself on Crs. Therefore, the aim of the study was to assess if Crs in COVID ARDS and non-COVID ARDS is similar or different when the applied PEEP is taken into account.

Methods

In this retrospective cohort study, data was collected from all consecutive adult subjects (over 18 years of age) with a diagnosis of ARDS (according to the Berlin Definition criteria [13]) to the Intensive Care Unit (ICU) of Poliambulanza Foundation Hospital of Brescia (Lombardy, Italy) from January 1st 2015 to May 1st 2021.The referral Ethics Committee (Comitato Etico di Brescia) approved the study (protocol number 4893).

Subjects were excluded from the analysis if: (a) they did not undergo invasive mechanical ventilation with sedation and paralysis; (b) no recordings of Crs at different PEEP levels during invasive ventilation with sedation and paralysis during the ARDS period were available.

Two cohorts of subjects were created: (1) subjects with COVID-19 ARDS, i.e., the ones with ARDS attributable to Severe Acute Respiratory Syndrome–CoronaVirus- 2 (SARS-CoV -2) infection. (2) subjects with non-COVID ARDS, i.e., ARDS subjects without SARS-CoV 2 infection. ARDS patients were included in this group if ICU admission occurred before February 18th 2020, the day of the first COVID-19 diagnosis in our region (RT-PCR test for SARS-CoV-2 was not performed before this date), or if they had a negative RT-PCR test for SARS-CoV-2 after 18th February 2021.

Data on respiratory mechanics were collected, on median, on the same day as ARDS diagnosis in both COVID ARDS and non-COVID ARDS (0 [0–1] and 0 [0–1] days after ARDS diagnosis, respectively, p = 0.51). Tracheal intubation was performed, on median, on the same day as ARDS diagnosis in patients with COVID ARDS and on the day before ARDS diagnosis in patients with non-COVID ARDS (0 [0–1] and 1 [0–1.5] days before ARDS diagnosis, respectively, p < 0.001).

All measurements were taken with patients in the semirecumbent position, sedated and paralyzed. Ventilatory settings were adjusted according to our ICU’s ventilation protocol [4]: Crs at different PEEP levels was assessed with a “PEEP trial”, setting volume controlled ventilation if not in use and maintaining the tidal volume set by the attending clinician in order to ensure a low-tidal volume ventilation. An end-inspiratory pause of 0.5 s was set and the respiratory rate was progressively decreased until complete exhalation was achieved. A stepwise increase (of 2 cmH2O) in PEEP level was performed, until an evident pattern of decrease of Crs with increasing PEEP was noticeable. The lowest PEEP level at which Crs was assessed in all patients was 4 cmH2O. A PEEP of 0 and 2 cmH2O could be applied in patients with SpO2 higher than 85%. Each PEEP level was maintained for at least 2 min [14]. When the PEEP trial was completed, the previous ventilatory mode and respiratory rate were restored, and PEEP was set to obtain a total PEEP equal to the PEEP associated with the highest Crs obtained during the PEEP trial. The PEEP trial was stopped when a systematic increase in driving pressure was seen with increasing PEEP, or when adverse cardiovascular effects or a decrease in SpO2 greater than 10% of baseline were noticed.

The “PEEP trial” was completed, on median, on the same day as intubation in all groups.

Data (demographic, clinical, laboratory data and outcome) were extracted from the electronic medical chart of enrolled subjects.

Measurements and calculations

Respiratory system compliance (Crs) was calculated as the ratio between tidal volume and driving pressure, which is the pressure distending the lungs, and is calculated as end inspiratory pressure (Plateau Pressure) minus PEEP [7].

“Best compliance” was identified as the highest Crs obtained at the tested PEEP levels and “best minimum PEEP” was the lowest PEEP with which the best compliance was obtained in each patient.

Body mass index (BMI) was calculated as kg/m2, where kg is the weight in kilograms and m2 is the square of the height in meters.

Ideal Functional Residual Capacity (FRC) was calculated as 2.34·height in meters + 0.01·age in years − 1.09 in male patients and as 2.24·height in meters + 0.001·age in years − 1.00 in female patients [15]. Predicted FRC was obtained correcting for BMI with the following formula 231.9·e(−0.070·BMI) + 55.2 [16].

Ventilatory ratio was calculated as (tidal volume·respiratory rate·PaCO2)/(ideal body weight·100 ml/min·37.5 mmHg), where tidal volume is expressed in milliliters and 37.5 is assumed to be the PaCO2 during the ideal minute ventilation [17].

Ideal body weight (IBW) was calculated as 50 + (0.91·[height in centimeters − 152.4]) for men, and as 45.5 + (0.91·[height in centimeters − 152.4]) for women.

Study outcomes

The main study outcome was to assess if the Crs of the respiratory system was independently associated with the type of ARDS (COVID ARDS or non-COVID ARDS) when weighted for PEEP level and patients’ baseline characteristics.

Statistical analysis

Sample size analysis was conducted with Montecarlo simulation based on data collected for a previous study [4]. Two hundred and sixty patients, hypothesising a ratio between COVID and non-COVID ARDS of 0.30, would guarantee a power of 0.80 to identify a difference in Crs between the two groups of 5 ml/cmH2O, with a type I error frequency of 0.05.

Data are shown as count (percentage) or median (interquartile range) and comparison between non-COVID ARDS and COVID ARDS were performed with χ2 test and Wilcoxon rank-sum test, respectively.

We planned to analyze the association between Crs and type of ARDS at different PEEP levels, using linear mixed models. The dependent variable was Crs and the following covariates were chosen a priori: type of ARDS (COVID vs non-COVID), PEEP, age, sex, BMI, Ventilatory Ratio, tidal volume, PaO2/FIO2, with patients as random effect.

Two secondary analyses were planned, with the aim to repeat the analysis on matched samples: (1) two cohorts of non-COVID and COVID ARDS were created, matched for predicted FRC. Matching was performed with the nearest neighbor method. The association between Crs and the type of ARDS (COVID versus non-COVID) was assessed with linear mixed models with interaction, using the type of ARDS and PEEP level at which Crs was measured as covariate, and patients as random effect. (2) The average respiratory system compliance (Crs,avg) was calculated in each patient at a PEEP level of 0, 5, 10, and 15 cmH2O, taking the average Crs obtained at a PEEP of 0, 5, 10 and 15 cmH2O ± 2 cmH2O. The association between Crs,avg and type of ARDS (COVID versus non-COVID) was reassessed at each of the four PEEP levels with linear model weighted with stabilized Inverse Probability Treatment Weighting obtained by propensity score [18]. Propensity score was calculated using age, sex, BMI, Ventilatory Ratio, tidal volume (used in the PEEP trial) and PaO2/FIO2 as covariates.

The analyses were repeated excluding non-COVID patients with extrapulmonary ARDS.

Missing values were imputed with Multivariate Imputation by Chained Equations (Predictive Mean Matching). A p value lower than 0.05 was considered significant. Statistical analyses were performed with R 3.6.3 (R Core Team, 2021. R Foundation for Statistical Computing, Vienna) [19].

Results

Three hundred sixty seven subjects were included in the study, 276 with COVID-ARDS and 91 with non-COVID ARDS (Fig. 1). Patient characteristics are shown in Table 1. In 24% of non-COVID ARDS patients, the cause of ARDS was extrapulmonary. Mean arterial pressure, central venous pressure, number of patients on norepinephrine and norepinephrine dose (mcg·kg−1·min−1) and daily urine output did not differ between COVID and non-COVID ARDS patients. Heart rate and lactate had a statistically significant difference, which we believe is clinically insignificant (median heart rate 92 beats·minute [IQR 78, 105] and 83 [IQR 69, 97] in non-COVID and COVID ARDS, respectively, p = 0.001; median lactate 1.1 [IQR 0.9, 1.7] mmol·l−1 and 0.9 [ IQR 0.8, 1.2] mmol·l−1 in non-COVID and COVID ARDS, respectively, p = 0.001).

Fig. 1
figure 1

Flowchart of patients included in the study. PEEP positive end expiratory pressure, ARDS acute respiratory distress syndrome

Table 1 Patient characteristics

Figure 2 shows Crs at different PEEP levels in non-COVID ARDS and COVID ARDS, in all enrolled patients and in the subset of patients which were matched for predicted FRC. The association between Crs and type of ARDS was not significant in both the complete cohorts (p = 0.17, see Additional file 1: Table S1) nor in the matched cohorts (p = 0.93, see Additional file 1: Table S2).

Fig. 2
figure 2

Crs at different PEEP levels. Linear regression showing Crs at different PEEP levels in non-COVID ARDS and COVID ARDS, in all enrolled patients and in the subset of patients which were matched for predicted FRC. 0 = non-COVID ARDS patients, 1 = COVID ARDS patients. Crs respiratory system compliance, PEEP positive end expiratory pressure, ARDS acute respiratory distress syndrome, FRC functional residual capacity

Table 2 shows the results of the propensity score weighted association between Crs,avg and COVID status at different PEEP levels. Crs,avg was not associated with the ARDS type at PEEP 5, 10 and 15 cmH2O, showing a significant association at PEEP 0, despite a clinically insignificant difference. Estimates for the other variables are displayed in Additional file 1: Table S3.

Table 2 Results of the propensity score weighted association between Crs,avg and COVID status at different PEEP levels

Figure 3 shows the distribution of Crs,avg at different PEEP levels.

Fig. 3
figure 3

Distribution of Crs at different PEEP levels. 0 = non-COVID ARDS patients, 1 = COVID ARDS patients. Crs respiratory system compliance, PEEP positive end expiratory pressure, ARDS acute respiratory distress syndrome, FRC functional residual capacity

Results of the analyses excluding non-COVID patients with extrapulmonary ARDS are shown in Additional file 1: Tables S4–S7).

Updating the power analysis with collected data, we reached a power of 0.85 in detecting a change in compliance of 4 ml/cmH2O between COVID and non-COVID ARDS, with a type I error frequency of 0.05.

Discussion

This study shows that Crs is similar between COVID ARDS and non-COVID ARDS when weighted for PEEP level and patients’ baseline characteristics.

Previous studies comparing compliance between COVID-ARDS and non-COVID ARDS have shown conflicting results [3, 5, 12, 20], and the debate is still ongoing.

In particular, Haudebourg et al. [3] found similar Crs between the COVID and non-COVID ARDS patients, with values close to the ones found in our study (44 ml/cmH2O in COVID e 42 ml/cmH2O in non-COVID patients in their study, versus 40 ml/cmH2O in COVID e 38 ml/cmH2O in non-COVID in our study). However, the authors did not adjust for patient characteristics, the cohorts were small (30 with COVID-ARDS versus 30 with non-COVID ARDS) and patients were not matched. In another work comparing COVID and non-COVID ARDS patients [20], the two cohorts were matched on PaO2/FiO2, FiO2, PEEP and tidal volume, but there was no adjustment for patient characteristics. Higher (7 ml/cmH2O) average values of Crs were found in COVID-19 patients, but the sample size was small (30 patients) and set and total PEEP were different between COVID and non-COVID patients for both high and low PEEP levels. Other authors [5] found a higher median Crs in patients with COVID-19 (41 ml/cmH2O) than in those with classical ARDS (32 ml/cmH2O). The analysis was adjusted for sequential organ failure assessment score at ICU admission, sex, age, and PaO2/FiO2 ratio, but PEEP selection was not protocolized in their patients. Ferrando et al. [12] found a tendency towards the statistical significance (p 0.06) by comparing the Crs of non-COVID ARDS patients from different studies and the authors’ own data on COVID ARDS patients.

Apart from the intrinsic mechanical properties of the respiratory system, Crs is affected by applied PEEP [7,8,9,10,11]. COVID and non-COVID patients often receive different PEEP levels during mechanical ventilation [4, 20] therefore the comparison of Crs at different PEEP levels could reflect not only the impact of the disease on lung parenchyma but also the effects of the ventilatory treatment. Finding a similar Crs with a different applied PEEP in COVID and non-COVID ARDS [4] does not therefore exclude that the elastic properties of the respiratory system would have been different if the same level of positive pressure had been applied. On the other hand, a different Crs in COVID and non-COVID ARDS measured at a different PEEP levels cannot exclude similar mechanical properties of the respiratory system if the conditions of measurement had been the same [20].

Moreover, Crs depends on the FRC: the physiological variable which links compliance to FRC is called specific compliance (the ratio between Crs and FRC) [21,22,23]. Crs is dramatically different in healthy subjects with different FRCs, ranging on average between 5 and 7 ml/cmH2O in newborns [20] and 120 ml/cmH2O in adults [21]. When Crs is normalized by FRC, specific elastance (i.e., the ratio betweenFRC and Crs) has similar values in healthy newborns, children and adults [24]. In other words, despite similar elastic properties for each milliliter of lung tissue, the same amount of applied pressure gives a different increase in volume (and therefore of Crs) if the FRC is different. Matching for predicted FRC is meaningful when Crs is compared in COVID and non-COVID ARDS because FRC depends on height, age, sex and BMI [15, 16, 25], and some of these characteristics have been shown to be different in COVID and non-COVID ARDS (mainly sex and BMI) [5].

The effect of a different predicted FRC could explain the findings of Li Bassi et al. [26] who found, in their analysis on COVID-19 ARDS patients, a lower Crs in female patients: on average, females have a smaller stature than males, and this predicts lower FRC. Moreover, female sex by itself gives a lower predicted FRC than male sex for the same height and age, whereas BMI, which was higher for female patients in Li Bassi’s cohort, has an inverse relationship with predicted FRC. Therefore a lower Crs in female patients could be better explained by different anthropometric characteristics than by a different severity of the lung disease.

Based on these pathophysiological premises and clinical data, we designed an analysis which accounted for the effect of both PEEP and FRC.

Our analyses showed that Crs is not different between COVID and non-COVID ARDS if assessed at a similar PEEP level when the association was weighted for covariates, when it was carried out in a cohort matched for predicted FRC and when the inverse probability of treatment weighting was used to obtain unbiased estimates of average treatment effects. These results contribute to clarify the debate on the effect of the COVID-19 on alveolar damage, demonstrating that the inflammatory response involving the pulmonary parenchyma in ARDS affects the mechanical properties of the lung regardless of the primary disease. This is consistent with the pattern and definition of ARDS, which is considered as the common final pathway of different pulmonary and extrapulmonary diseases that spread their mediators of inflammation in the lungs [13, 27].

The similar pattern of Crs in COVID and non-COVID ARDS is supported by a similar best Crs obtained during the PEEP trial (median 38 versus 40 ml/cmH2O in non-COVID and COVID ARDS, respectively; see Table 1 for further details), and by a similar lowest PEEP at which the best Crs was obtained.

As shown in Fig. 3 it is apparent that, for some patients, a high PEEP level worsens respiratory system compliance, while improving it for some patients. We can therefore speculate that the appearance of two “phenotypes” is in fact the effect of a high PEEP level, and not of COVID ARDS itself, but further studies are needed to prove these findings.

Primary analysis was also weighted on dead space, as estimated by Ventilatory Ratio [17], since one of the main differences between COVID and non-COVID ARDS appears to be the dead space ventilation, expression of altered perfusion and vascular endothelial injury [4, 5, 28]. The peculiar increase in dead space ventilation of COVID-19 has been explained as a consequence of pulmonary microvascular thrombosis which locally increases the ventilation/perfusion ratio [5, 28, 29].

The dead space increase in COVID ARDS compared with non-COVID ARDS is confirmed in our analysis, with a higher ventilatory ratio in COVID ARDS compared to non-COVID ARDS in both unmatched and matched cohorts.

This study has two main limitations. First, it is a single center study and therefore requires further confirmation. Nonetheless, since we analyzed the association of Crs and type of ARDS for a wide range of PEEPs, we believe that our data could be generalized to centers which use a different approach to mechanical ventilation. Second, it is a retrospective study, even if data was prospectively collected. More research is needed on the subject in order to corroborate these findings.

Conclusion

The compliance of the respiratory system is similar between COVID ARDS and non-COVID ARDS when calculated at the same PEEP level and while taking into account patients’ anthropometric characteristics.

Availability of data and materials

The datasets used and/or analysed during the current study are available from the corresponding author on reasonable request.

Abbreviations

ARDS:

Acute respiratory distress syndrome

COVID-19:

Novel coronavirus 2019 disease

Crs :

Respiratory system compliance

PEEP:

Positive end expiratory pressure

SARS-CoV -2:

Severe Acute Respiratory Syndrome–CoronaVirus- 2

RT-PCR:

Reverse transcriptase-polymerase chain reaction

ICU:

Intensiva care unit

FRC:

Functional residual capacity

BMI:

Body mass index

IBW:

Ideal body weight

Crs,avg :

Average respiratory system compliance

References

  1. Yang X, Yu Y, Xu J, Shu H, Xia J, Liu H, et al. Clinical course and outcomes of critically ill patients with SARS-CoV-2 pneumonia in Wuhan, China: a single-centered, retrospective, observational study. Lancet Respir Med. 2020;8:475–81.

    Article  CAS  Google Scholar 

  2. Gattinoni L, Chiumello D, Caironi P, Busana M, Romitti F, Brazzi L, et al. COVID-19 pneumonia: different respiratory treatments for different phenotypes? Intensive Care Med. 2020;46:1099–102.

    Article  CAS  Google Scholar 

  3. Haudebourg A-F, Perier F, Tuffet S, de Prost N, Razazi K, Mekontso Dessap A, et al. Respiratory mechanics of COVID-19– versus non–COVID-19–associated acute respiratory distress syndrome. Am J Respir Crit Care Med. 2020;202:287–90.

    Article  CAS  Google Scholar 

  4. Bertelli M, Fusina F, Prezioso C, Cavallo E, Nencini N, Crisci S, et al. COVID-19 ARDS is characterized by increased dead space ventilation compared with non-COVID ARDS. Respir Care. 2021;66:1406–15.

    Article  Google Scholar 

  5. Grasselli G, Tonetti T, Protti A, Langer T, Girardis M, Bellani G, et al. Pathophysiology of COVID-19-associated acute respiratory distress syndrome: a multicentre prospective observational study. Lancet Respir Med. 2020;8:1201–8.

    Article  CAS  Google Scholar 

  6. Baedorf Kassis E, Schaefer MS, Maley JH, Hoenig B, Loo Y, Hayes MM, et al. Transpulmonary pressure measurements and lung mechanics in patients with early ARDS and SARS-CoV-2. J Crit Care. 2021;63:106–12.

    Article  CAS  Google Scholar 

  7. Hess DR. Respiratory mechanics in mechanically ventilated patients. Respir Care. 2014;59:1773–94.

    Article  Google Scholar 

  8. Grasso S, Fanelli V, Cafarelli A, Anaclerio R, Amabile M, Ancona G, et al. Effects of high versus low positive end-expiratory pressures in acute respiratory distress syndrome. Am J Respir Crit Care Med. 2005;171:1002–8.

    Article  Google Scholar 

  9. Kuckelt W, Scharfenberg J, Mrochen H, Dauberschmidt R, Petrakov G, Kassil W, et al. Effect of PEEP on gas exchange, pulmonary mechanics, and hemodynamics in adult respiratory distress syndrome (ARDS). Intensive Care Med. 1981;7:177–85.

    Article  CAS  Google Scholar 

  10. Suter PM, Fairley HB, Isenberg MD. Optimum end-expiratory airway pressure in patients with acute pulmonary failure. N Engl J Med. 1975;292:284–9.

    Article  CAS  Google Scholar 

  11. Mergoni M, Martelli A, Volpi A, Primavera S, Zuccoli P, Rossi A. Impact of positive end-expiratory pressure on chest wall and lung pressure–volume curve in acute respiratory failure. Am J Respir Crit Care Med. 1997;156:846–54.

    Article  CAS  Google Scholar 

  12. Ferrando C, Suarez-Sipmann F, Mellado-Artigas R, Hernández M, Gea A, Arruti E, et al. Clinical features, ventilatory management, and outcome of ARDS caused by COVID-19 are similar to other causes of ARDS. Intensive Care Med. 2020;46:2200–11.

    Article  CAS  Google Scholar 

  13. ARDS Definition Task Force. Acute respiratory distress syndrome: the Berlin definition. JAMA. 2012;307:2526–33.

    Google Scholar 

  14. Garnero A, Tuxen D, Corno G, Durand-Gasselin J, Hodgson C, Arnal J-M. Dynamics of end expiratory lung volume after changing positive end-expiratory pressure in acute respiratory distress syndrome patients. Crit Care. 2015;19:340.

    Article  Google Scholar 

  15. Stocks J, Quanjer PhH. Reference values for residual volume, functional residual capacity and total lung capacity. Eur Respir J. 1995;8:492–506.

    Article  CAS  Google Scholar 

  16. Jones RL, Nzekwu M-MU. The effects of body mass index on lung volumes. Chest. 2006;130:827–33.

    Article  Google Scholar 

  17. Sinha P, Calfee CS, Beitler JR, Soni N, Ho K, Matthay MA, et al. Physiologic analysis and clinical performance of the ventilatory ratio in acute respiratory distress syndrome. Am J Respir Crit Care Med. 2019;199:333–41.

    Article  Google Scholar 

  18. Li F, Morgan KL, Zaslavsky AM. Balancing covariates via propensity score weighting. J Am Stat Assoc. 2018;113:390–400.

    Article  CAS  Google Scholar 

  19. R Core Team. R: A Language and Environment for Statistical Computing. Vienna, Austria: R Foundation for Statistical Computing; 2021. at https://www.R-project.org/.

  20. Grieco DL, Bongiovanni F, Chen L, Menga LS, Cutuli SL, Pintaudi G, et al. Respiratory physiology of COVID-19-induced respiratory failure compared to ARDS of other etiologies. Crit Care. 2020;24:529.

    Article  Google Scholar 

  21. Chiumello D, Carlesso E, Cadringher P, Caironi P, Valenza F, Polli F, et al. Lung stress and strain during mechanical ventilation for acute respiratory distress syndrome. Am J Respir Crit Care Med. 2008;178:346–55.

    Article  Google Scholar 

  22. Gattinoni L, Pesenti A, Avalli L, Rossi F, Bombino M. Pressure-volume curve of total respiratory system in acute respiratory failure: computed tomographic scan study. Am Rev Respir Dis. 1987;136:730–6.

    Article  CAS  Google Scholar 

  23. Suter PM, Fairley HB, Isenberg MD. Effect of tidal volume and positive end-expiratory pressure on compliance during mechanical ventilation. Chest. 1978;73:158–62.

    Article  CAS  Google Scholar 

  24. Phelan PD, Williams HE. Ventilatory studies in healthy infants. Pediatr Res. 1969;3:425–32.

    Article  CAS  Google Scholar 

  25. Lutfi MF. The physiological basis and clinical significance of lung volume measurements. Multidiscip Respir Med. 2017;12:3.

    Article  Google Scholar 

  26. Li Bassi G, Suen JY, Dalton HJ, White N, Shrapnel S, Fanning JP, et al. An appraisal of respiratory system compliance in mechanically ventilated COVID-19 patients. Crit Care. 2021;25:199.

    Article  Google Scholar 

  27. Ashbaugh David G, Boyd Bigelow D, Petty Thomas L, Levine BE. Acute respiratory distress in adults. The Lancet. 1967;290:319–23.

    Article  Google Scholar 

  28. Fusina F, Albani F, Bertelli M, Cavallo E, Crisci S, Caserta R, et al. Corrected minute ventilation is associated with mortality in the ARDS caused by COVID-19. Respir Care. 2021;66:619–25.

    Article  Google Scholar 

  29. Ackermann M, Verleden SE, Kuehnel M, Haverich A, Welte T, Laenger F, et al. Pulmonary vascular endothelialitis, thrombosis, and angiogenesis in COVID-19. N Engl J Med. 2020;383:120–8.

    Article  CAS  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

No funding was received for this study.

Author information

Authors and Affiliations

Authors

Contributions

All authors contributed to the data acquisition. FF and GN drafted the manuscript. GN designed and supervised the study. FA and GN conducted the data analysis. All authors contributed substantially to editing, revising and finalizing the manuscript before submission. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Federica Fusina.

Ethics declarations

Ethics approval and consent to participate

The protocol was approved by the local ethical committee (Comitato Etico della Provincia di Brescia) with protocol number 4893.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Additional file 1.

Supplementary Material.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Fusina, F., Albani, F., Crisci, S. et al. Respiratory system compliance at the same PEEP level is similar in COVID and non-COVID ARDS. Respir Res 23, 7 (2022). https://0-doi-org.brum.beds.ac.uk/10.1186/s12931-022-01930-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://0-doi-org.brum.beds.ac.uk/10.1186/s12931-022-01930-0

Keywords