Reference | Viscosity (cP) | Device | Technique |
---|---|---|---|
Human (recurrent bronchitis) (Puchelle et al. 1981) [26] | 2.48 × 104 | Concentric cylinder rheometer | Shear deformation at a shear rate of 0.3 s−1 |
Human (mild chronic bronchitis) (Puchelle et al. 1981) [26] | 1.14 × 104 | Concentric cylinder rheometer | |
Human (severe chronic bronchitis) (Puchelle et al. 1981) [26] | 1.25 × 104 | Concentric cylinder rheometer | |
Human (Baconnais et al. 1999) [27] | 200 | Cone and plate rheometer | Creep-test under a constant stress of 10 Pa |
Human (CF) (Baconnais et al. 1999) [27] | 600 | Cone and plate rheometer | |
Human (Jeanneret-Grosjean et al.1988) [16] | (1.2~1.5) × 104 | Magnetic microrheometer | Oscillating a steel microsphere at 1 and 100 rad/s |
Human (CF) (Dawson et al. 2003) [28] | ~ 7 × 104 | Cone and plate rheometer | Shear deformation at a shear rate of 10− 2~102 rad/s |
Human (CF) (Feather et al. 1970) [29] | 21~134 | Cone and plate rheometer | Shear deformation at a shear rate of 900 s−1 |
Human (chronic bronchitis) (Feather et al. 1970) [29] | 117~144 | Cone and plate rheometer | |
Human (bronchiectasis) (Feather et al. 1970) [29] | 58 | Cone and plate rheometer | |
Human (ARDS) (author’s labs) | 0.97~ 7.76 × 104 | Cone and plate rheometer | Shear deformation at a shear rate of 10− 2~10 rad/s |