Objective cough frequency has been reported in several respiratory conditions but the amount that healthy individuals cough daily is unclear. Seventy-nine healthy volunteers (38 males, median [IQR] age 41y [IQR 30–53]) completed 24-hour ambulatory cough monitoring (VitaloJAK™). The audio recording was filtered using a custom written algorithm to remove non-cough sounds and then all individual explosive cough sounds in the filtered file were tagged electronically by trained cough counters. Most coughing occurred during the day and cough numbers over 24 h were generally low (geometric mean of 4.6 coughs) but there was large variability; ranging from 0 to 136 coughs overall. Cough frequency was independent of participant characteristics apart from sex with males coughing significantly, 4–5 fold, more than females during the day and over 24 h (median [IQR] 16.1 [3.8–33.4] vs. 4.1 [1.0–15.0] total coughs; p = 0.015). This is the first report to describe cough frequency in a balanced group of healthy adults using an accurate cough monitoring system. The data reveal a further example of sexual dimorphism in cough, which warrants additional investigation.

Correspondence

Developments in cough quantification systems have significantly improved the way new treatments for cough are evaluated and cough mechanisms are studied. Objective 24-hour cough frequency has been measured in patients with various respiratory conditions [1,2,3,4] however it is unclear how much healthy people cough daily. It would be useful to understand normal cough frequency for several reasons. There may be clinical value in identifying thresholds at which cough frequency is more likely to be excessive and therefore represents pathology. In addition, there has recently been significant development in novel medications for the treatment of chronic cough and such a threshold may be helpful in determining patient inclusion criteria for clinical trials [5]. Furthermore, in respiratory disease outbreaks such as the COVID-19 pandemic, the frequency of coughing in health suggests the potential for transmission of virus by asymptomatic or pre-symptomatic individuals.

Only a few previous studies have reported spontaneous cough frequency in healthy volunteers but they were carried out in small sample sizes, using cough monitoring devices not fully validated, and one study was in children [1, 6, 7]. Therefore, the aim of this analysis was to accurately report cough frequency in a group of healthy people and evaluate the influence of participant characteristics such as age and sex. The data for this report were collected as part of a study reported previously [8] investigating cough responses to inhaled irritants (REC ref; 13/NW/0400). Cough monitoring was carried out at baseline, prior to any cough challenge testing. All participants provided written informed consent.

Healthy volunteers were recruited from staff, students and databases of volunteers who had previously consented to be approached for future research. Inclusion criteria comprised normal spirometry (FEV1 and FVC ≥ 80% predicted), no recent respiratory tract infection (< 4 weeks) and no significant current or past medical history that in the opinion of the investigators would affect the study (including respiratory disease, chronic cough, chronic pain, irritable bowel syndrome, psychiatric illness, chronic headaches, diabetes, cardiac or cerebrovascular disease). Current smokers, ex-smokers with > 20 pack year history and/or < 6 months abstinence and those taking cough-modulating medications (including angiotensin-converting enzyme inhibitors, opiates and centrally acting antidepressants) were excluded.

Participants were fitted with an ambulatory cough monitor (VitaloJAK™, Vitalograph, UK) for 24 h. At the end of the recording, the audio file was filtered by a custom-written algorithm to remove non-cough sounds and silence [9] and then analysed by trained cough counters who manually placed electronic tags on each individual explosive cough sound. The algorithm retains a median 100% of coughs (IQR 99.5–100) [9] and agreement for cough counting between trained cough analysts is excellent [10]. The number of cough tags was totalled and the times that participants retired to bed and woke up were determined by listening to sections of the 24 h audio recording in order to calculate daytime and night-time cough frequency.

Data were summarised using means (standard deviation), medians (interquartile range), geometric means (95% confidence intervals) and ranges. The influence of sex was analysed using Mann-Whitney U tests. Cough frequencies were correlated (Spearman’s) with participant characteristics (age, BMI, smoking history, lung function). The upper limit of normal for cough frequency was estimated by calculating 95th percentiles.

Seventy-nine healthy participants (38 males) were enrolled; median (IQR) age 41y (IQR 30–53, range 20–74); BMI 25.4 (22.4–28.6). Lung function was normal; median(IQR) FEV1 and FVC were 104 (96–115) and 107 (100–121) % predicted and smoking history was minimal; median(IQR) pack year history was 0.0 (0.0–0.0) with 14 volunteers being former smokers. Most participants had low cough numbers over 24 h; a median total count of 7 coughs; 0.3 coughs/hour (c/h) (Table 1). Three quarters of subjects coughed less than 30 times and eight people (~ 10%) did not cough at all in 24 h. However, there was considerable variability in the numbers of coughs recorded (Fig. 1), particularly in males who exhibited 4-5-fold more coughs than females during the day and over 24 h (median [IQR] 16.1 [3.8–33.4] vs. 4.1 [1.0–15.0] total coughs; p = 0.015). Most coughing occurred during the day; night-time cough was scarce and did not differ between sexes. There were no significant correlations between cough frequency and any of the characteristics recorded (age/BMI/smoking history/FEV1%/FVC%), except that BMI weakly correlated with the coughing at night (r = 0.3, p = 0.007).

Table 1 Total (24 h), daytime and night-time cough frequencies for males (n = 38), females (n = 41) and all 79 participants combined; displayed as mean (standard deviation; SD), geometric mean (95% confidence interval; CI), median (interquartile range; IQR) and range (minimum to maximum values). P values indicate differences between sexes compared using Mann-Whitney U test
Fig. 1
figure 1

Frequency distribution of total numbers of coughs in 24 h comparing males with females. Relative frequency was calculated as a proportion of the total number of participants for each gender (n = 38 females and n = 41 males)

Based on the 95th percentile, the upper limit of normal for total cough frequency was 63 coughs over 24 h (2.6 c/h). Due to the differences observed between sexes, the upper limits calculated separately for males and females were 111 (4.6 c/h) and 45 (1.9c/h) coughs respectively.

This is the first report to present 24-hour objective cough frequency in a large group of adult healthy controls. Cough frequency was accurately quantified using an FDA approved and CE marked, semi-automated cough monitoring system, validated in several disease groups including healthy volunteers [9]. The amount of coughing was quite variable with some individuals not coughing at all whilst 136 coughs were recorded in one individual. In keeping with previous findings, most coughing occurred during waking hours, with very little at night. Cough frequency was independent of participant characteristics apart from sex.

Notably, males coughed significantly more than females during waking hours, and over 24 h. This contrasts with studies of cough responses to inhaled irritants such as capsaicin which have shown healthy females have a more sensitive and responsive cough reflex when evoked experimentally [11]. Indeed, specialist cough clinics are predominantly attended by females who also exhibit significantly higher cough frequencies than men with chronic cough [11]. It is impossible to explain this difference from our study, however perhaps sub-clinical or undiagnosed conditions were more prevalent in the males than females. The correlation between overnight cough and BMI might implicate conditions such as obstructive sleep apnoea and gastro-oesophageal reflux.

This study has some limitations. Participants were only recorded on a single occasion and so repeatability of cough frequency in healthy volunteers was not established. Also, it is possible that the awareness of having their cough monitored altered the amount of coughing observed.

To the best of our knowledge, only two previous studies have quantified spontaneous cough frequency in healthy adults. Hsu et al. studied 12, mostly male, healthy controls only reporting a range of 0–16 coughs per day [1]. As no further information was reported, it is difficult to compare this data to our findings. More recently, Yousaf and colleagues reported a geometric mean of 18.6 coughs per 24 h in 44 (27% female) healthy subjects [7]. In the latter study, females coughed more than males however, as acknowledged in the report, the sensitivity for cough detection was only 83.8% and the relatively large number of false positives likely inflated the cough counts. Our dataset is larger and more balanced for sex compared with previous studies and, together with precise cough monitoring provides the most accurate estimate of cough frequency in healthy people to date. Our data also reveal a further example of sex differences in cough, which warrant additional investigation.

Data Availability

The datasets used and/or analysed during the current study are available from the corresponding author on reasonable request.

Abbreviations

BMI:

Body mass index

CI:

Confidence interval

FDA:

Food and drug administration

FVC:

Forced vital capacity

FEV1:

Forced expiratory volume in 1 second

IQR:

Interquartile range

REC:

Research ethics committee

SD:

Standard deviation

References

  1. Hsu JY, Stone RA, Logan-Sinclair RB, Worsdell M, Busst CM. Chung K. F. Coughing frequency in patients with persistent cough: assessment using a 24 hour ambulatory recorder. Eur Respir J. 1994;7(7):1246–53.

    Article  CAS  PubMed  Google Scholar 

  2. Sumner H, Woodcock A, Kolsum U, Dockry R, Lazaar AL, Singh D, Vestbo J, Smith JA. Predictors of objective cough frequency in Chronic Obstructive Pulmonary Disease. Am J Respir Crit Care Med. 2013;187(9):943–9.

    Article  PubMed  Google Scholar 

  3. Smith JA, Owen EC, Jones AM, Dodd ME, Webb AK, Woodcock A. Objective measurement of cough during pulmonary exacerbations in adults with cystic fibrosis. Thorax. 2006;61(5):425–9.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  4. Key AL, Holt K, Hamilton A, Smith JA, Earis JE. Objective cough frequency in Idiopathic Pulmonary Fibrosis. Cough. 2010;6:4.

    Article  PubMed  PubMed Central  Google Scholar 

  5. McGarvey LP, Birring SS, Morice AH, Dicpinigaitis PV, Pavord ID, Schelfhout J, Nguyen AM, Li Q, Tzontcheva A, Iskold B, Green SA, Rosa C, Muccino DR, Smith JA, Cough, Investigators Cough-. Efficacy and safety of gefapixant, a P2X3 receptor antagonist, in refractory chronic cough and unexplained chronic cough (COUGH-1 and COUGH-2): results from two double-blind, randomised, parallel-group, placebo-controlled, phase 3 trials. Lancet. 2022;399(10328):909–23.

    Article  PubMed  Google Scholar 

  6. Munyard P, Bush A. How much coughing is normal? Arch Dis Child. 1996;74(6):531–4.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  7. Yousaf N, Monteiro W, Matos S, Birring SS. Pavord I. D. Cough frequency in health and Disease. Eur Respir J. 2013;41(1):241–3.

    Article  PubMed  Google Scholar 

  8. Holt KJ, Belcher J, Smith JA. Novel capsaicin cough endpoints effectively discriminate between healthy controls and patients with refractory chronic cough. Respir Med. 2023;208:107142.

    Article  PubMed  Google Scholar 

  9. Smith JA, Holt K, Dockry R, Sen S, Sheppard K, Turner P, Czyzyk P. McGuinness K. Performance of a digital signal processing algorithm for the accurate quantification of cough frequency. Eur Respir J. 2021;58(2).

  10. Smith J, Thornton H, Keane F, Grant T, Crispino G, Dockry R, McGuinness K, Holt K. Reliability of Manual Cough counting using the VitaloJAK Cough Monitor. Am J Respir Crit Care Med. 2021;203:A2361.

    Google Scholar 

  11. Kelsall A, Decalmer S, McGuinness K, Woodcock A, Smith JA. Sex differences and predictors of objective cough frequency in chronic cough. Thorax. 2009;64(5):393–8.

    Article  CAS  PubMed  Google Scholar 

Download references

Funding

This study received support from the NIHR Manchester Clinical Research Facility and the NIHR Manchester Biomedical Research Centre (funding KH/JAS). JAS is also funded by a Wellcome Investigator Award (207504/B/17/Z) and is an NIHR Senior Investigator.

Author information

Authors and Affiliations

Authors

Contributions

KH and JAS both designed the study, developed the protocol, collected the data, analysed the data, devised and agreed the final version of the manuscript.

Corresponding author

Correspondence to Kimberley J. Holt.

Ethics declarations

Competing interests

The VitaloJAK algorithm has been licensed by Manchester University Foundation Trust (MFT) and the University of Manchester to Vitalograph Ltd and Vitalograph Ireland (Ltd). MFT receives royalties which may be shared with the clinical division in which JAS works.

Clinical Trial Registration

www.isrctn.com; ISRCTN23684347.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Holt, K.J., Smith, J.A. How often do healthy people cough?. Respir Res 24, 275 (2023). https://0-doi-org.brum.beds.ac.uk/10.1186/s12931-023-02585-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://0-doi-org.brum.beds.ac.uk/10.1186/s12931-023-02585-1

Keywords